IDevice

Create an instance of the IDevice from CoreAPI.getDeviceList() or from CoreAPI.createDevice(). Then use the functions described in this chapter.

cancelTransaction

This function cancels a transaction. A transaction can only be cancelled before a card is presented.

bool IDevice.cancelTransaction();

Return Value:

Returns true if cancelled. Otherwise, returns false.

getCapabilities

This function retrieves the capabilities of the device.

IDeviceCapabilities IDevice.getCapabilities();

Return Value:

Returns IDeviceCapabilities

getConnectionInfo

This function retrieves the connection information of the device.

ConnectionInfo IDevice.getConnectionInfo();

Return Value:

Returns ConnectionInfo

getConnectionState

This function retrieves the connection state of the device.

ConnectionState IDevice.getConnectionState();

Return Value:

Returns ConnectionState

getDeviceConfiguration

This function allows the host to get an IDeviceConfiguration to configure the device.

IDeviceConfiguration IDevice.getDeviceConfiguration();

Return Value:

Returns IDeviceConfiguration.

This function retrieves the device control interface to the device.

Return Value:

Returns IDeviceControl

This function returns an information class of the device.

eturn Value:

Returns DeviceInfo.

This function returns the name of the device assigned from createDevice().

Return Value:

Returns the name of the device.

This function prompts the user to present their card and enter a PIN. A card is presented so that the device can retrieve the PAN, which is used for Format blocks requiring a PAN. The encrypted PIN block (EPB) will be returned in the event OnEvent(). The data byte array may be passed to builder function PANDataBuilder.GetPANData();

For DynaFlex devices, this function starts a PIN session on the first call and shall be called again to send the PIN status to the device for completing the PIN session.

PANRequest:

PINRequest:

Return Value:

Returns true if successful. Otherwise, returns false.

This function prompts the user to enter a PIN. The host must supply the PAN if the Format block selected requires a PAN. The encrypted PIN block (EPB) will be returned in the event OnEvent(). The data byte array may be passed to builder function PINDataBuilder.GetPINData();

For DynaFlex devices, this function starts a PIN session on the first call and shall be called again to send the PIN status to the device for completing the PIN session.

Return Value:

Returns true if successful. Otherwise, returns false.

This function prompts the user to enter a signature. The response data will be returned in the event OnEvent.

Return Value:

Returns true of success. Otherwise, returns false.

This function sends the Authorization Response Code (ARPC) blob to the device. The response data will be returned in the event OnEvent(). See 15.23C.4 Sample Code for how to process an EMV transaction.

Return Value:

Returns true if successful. Otherwise, returns false.

This function sends a command to an NFC Mifare Classic Tag type 2. The NFC tag must first be activated by calling startTransaction() with NFC enabled.

IData data,

bool lastCommand, bool encrypt);

Return Value:

Returns true if successful. Otherwise, returns false.

NFC Classic Commands

Response Data For NFC Mifare DESFire Light Tag Type 4

Example Unencrypted Payload

Example Encrypted Payload

This function sends a command to an NFC Mifare DESFire Light Tag Type 4. The NFC tag must first be activated by calling startTransaction() with NFC enabled.

Return Value:

Returns true if successful. Otherwise, returns false.

Response Data For NFC Mifare DESFire Light Tag Type 4

Example Unencrypted Payload

Example Encrypted Payload

This function sends a command to an NFC tag type 2. The NFC tag must first be activated by calling startTransaction() with NFC enabled.

Return Value:

Returns true if successful. Otherwise, returns false.

NFC Commands

Response Data For NFC Tag Type 2

Example Unencrypted Payload

Example Encrypted Payload

This function sends a command to a Mifare Plus NFC tag. The NFC tag must first be activated by calling startTransaction() with NFC enabled.

Return Value:

Returns true if successful. Otherwise, returns false.

This function sends a user selection to the device. The response data will be returned in the event OnEvent.

Return Value:

Returns true if successful. Otherwise, returns false.

This function starts a transaction. This function will automatically handle the opening and closing of a device. The transaction will be processed through multiple calls to the event OnEvent(). See 15.23C.4 Sample Code for how to process an EMV transaction.

ITransaction transaction);

Return Value:

Returns true if the transaction started successfully. Otherwise, returns false.

This function allows the host to be notified of all events sent by the device.

Return Value:

Returns true if successful. Otherwise, returns false.

This function allows the host to no longer receive any events sent by the device.

Return Value:

Returns true if successful. Otherwise, returns false.

Tone

byte

Tone to play when prompting for the PIN. Usage:

0x00 = No sound 0x01 = One beep 0x02 = Two beeps

NFC Data Container

/DF7A

var

NFC Data

If encrypted:

Tag

Len

Value / Description

/DFDF59

var

Encrypted Data Primitive to be decrypted.

/DFDF50

var

Encrypted Data KSN

/DFDF51

01

Encrypted Data Encryption Type

NFC Data Container

/DF7A

var

NFC Data

If encrypted:

Tag

Len

Value / Description

/DFDF59

var

Encrypted Data Primitive to be decrypted.

/DFDF50

var

Encrypted Data KSN

/DFDF51

01

Encrypted Data Encryption Type

Len

Value / Description

FC

var

NFC Data Container

/DF7A

var

NFC Data

If encrypted:

Tag

Len

Value / Description

/DFDF59

var

Encrypted Data Primitive to be decrypted.

/DFDF50

var

Encrypted Data KSN

/DFDF51

01

Encrypted Data Encryption Type

Parameter

Type

Description

Timeout

byte

Wait time in seconds.

Parameter

Type

Description

PaymentMethods

List of PaymentMethod

List of the PaymentMethod enumeration.

MSR = For magnetic stripe cards.

Contact = For EMV chip cards.

Contactless = For NFC contactless cards. ManualEntry = Manually entry, no card. When set, other payment methods must not be included.

Barcode = For barcode.

BarcodeEncrypted = For barcode with encrypted response.

AppleVAS = For Apple VAS.

GoogleVAS = For Apple VAS.

NFC = For NFC tag.

Parameter

Type

Description

Timeout

byte

Wait time in seconds.

PINMode

byte

PIN mode.

0x00 = Enter PIN

0x01 = Enter PIN Amount 0x02 = Reenter PIN Amount 0x03 = Reenter PIN

0x04 = Verify PIN

For DynaFlex devices this is the User Interface Sequence:

0x01 = Present Card / Enter PIN (start session)

0x04 = Present Card / Enter PIN / Enter PIN Again (start session)

On the second call to requestPAN(), send the PIN status:

0xFD = Cancel PIN Session (end session) 0xFE = PIN Entry Failed (end session) 0xFF = PIN Entry Successful (end session)

MinLength

byte

Minimum length of accepted PIN (>= 4).

MaxLength

byte

Parameter

Type

Description

Format

byte

ISO format for the PIN block.

0x00 = ISO Format 0 0x01 = ISO Format 1 0x03 = ISO Format 3 0x04 = ISO Format 4

PAN

String

First 12 digits of the Primary Account Number. Leave blank if not required by the ISO format for the PIN block.

Parameter

Type

Description

Tone

byte

Tone to play when prompting for the PIN.

0x00 = No sound 0x01 = One beep 0x02 = Two beeps

Format

byte

ISO format for the PIN block.

0x00 = ISO Format 0 0x01 = ISO Format 1 0x03 = ISO Format 3 0x04 = ISO Format 4

PAN

String

First 12 digits of the Primary Account Number. Leave blank if not required by the ISO format for the PIN block.

Parameter

Description

timeout

Time in seconds for the operation to complete.

0x01 to 0xFF

Parameter

Description

data

Contains ARPC blob.

Parameter

Description

data

Command to send to the NFC tag.

For details of the command see NFC commands table below or DynaFlex Family Programmer’s Manual section NFC/Mifare Pass Through Commands

lastCommand

Determines if this is the last NFC command to complete the operation.

true = This is the last command. Device will provide a single beep after receiving a successful response from the NFC tag. To send subsequent commands, the NFC tag must be activated by calling startTransaction() with NFC enabled.

false = Expect more commands (Default).

Either set to true or false, if the NFC tag command fails, device will provide a double beep.

encrypt

Determines if data returned is to be encrypted.

true = Encrypt data

false = Do not encrypt data (Default)

Command

Length

Field Value

Mifare Read

11

Byte 0 – 0x30 – Read Command Byte 1- Sector Number to Read Byte 2 – Start Block Number Byte 3 – End Block Number Byte 4 – Key Type, 0 = A, 1 = B Byte 5 to 10 = 6 Byte Key

Mifare Write

var

Byte 0 – 0xA0 – Write Command Byte 1- Sector Number to Write Byte 2 – Start Block Number Byte 3 – End Block Number

Byte 4 – Key Type 0 = A, 1 = B Byte 5 to 10 = 6 Byte Key

Byte 11 to x = Variable length Byte Data (16 bytes per block)

Command

Length

Field Value

Mifare Increment

14

Byte 0 – 0xC1 – Increment Command Byte 1 – Source Sector Number

Byte 2- Source Block number Byte 3 – Key Type 0 = A, 1 = B Byte 4 to 9 = 6 Byte Key

Byte 10 to 13 = 4 Byte Operand

Mifare Decrement

14

Byte 0 – 0xC0 – Decrement Command Byte 1 – Source Sector Number

Byte 2- Source Block number Byte 3 – Key Type 0 = A, 1 = B Byte 4 to 9 = 6 Byte Key

Byte 10 to 13 = 4 Byte Operand

Mifare Restore

10

Byte 0 – 0xC2 – Restore Command Byte 1 – Source Sector Number Byte 2 - Source Block number Byte 3 – Key Type 0 = A, 1 = B Byte 4 to 9 = 6 Byte Key

Mifare Transfer

10

Tag

Len

Value / Description

81

var

Tag Response Code. Byte 0 = 0x00 = Success

Byte 0 = 0x01 = I/O Failed

Byte 0 = 0x02 Authentication Failed

Byte 1 = 0x01 = Block that Failed (optional)

Tag

Len

Value / Description

82

var

Encryption Control Payload tag data.

Β· Data of R-APDU

If unencrypted:

Tag

Len

Value / Description

FC

Parameter

Description

data

Command to send to the NFC tag. See DESFire Data Sheet (MF2DLHX0). Should follow ISO 7816-4 APDU format.

For details of the command see

D998200383 DynaFlex Family Programmer’s Manual (COMMANDS) section NFC/Mifare Pass Through Commands

lastCommand

Determines if this is the last NFC command to complete the operation.

true = This is the last command. Device will provide a single beep after receiving a successful response from the NFC tag. To send subsequent commands, the NFC tag must be activated by calling startTransaction() with NFC enabled.

false = Expect more commands (Default).

Either set to true or false, if the NFC tag command fails, device will provide a double beep.

encrypt

Determines if data returned is to be encrypted.

true = Encrypt data

false = Do not encrypt data (Default)

Tag

Len

Value / Description

81

02

Tag Response (SW1 SW2). See DESFire Data Sheet (MF2DLHX0). Should follow ISO 7816-4 APDU format.

Β· SW1 and SW2 of R-APDU

If card is not able to respond:

Β· SW1 = 0x64, SW2 = 0x00

Tag

Len

Value / Description

82

var

Encryption Control Payload tag data

Β· Data of R-APDU

If unencrypted:

Tag

Len

Value / Description

FC

Parameter

Description

data

Command to send to the NFC tag.

  • Get Version

  • Read

  • Fast Read

  • Write

  • Compatibility Write

  • Read_Cnt

  • PWD_Auth

  • Read_Sig

For details of the command see the NFC commands table below or D998200383 DynaFlex Family Programmer’s Manual (COMMANDS) section NFC/Mifare Pass Through Commands

lastCommand

Determines if this is the last NFC command to complete the operation.

true = This is the last command. Device will provide a single beep after receiving a successful response from the NFC tag. To send subsequent commands, the NFC tag must be activated by calling startTransaction() with NFC enabled.

false = Expect more commands (Default).

Either set to true or false, if the NFC tag command fails, device will provide a double beep.

encrypt

Determines if data returned is to be encrypted.

true = Encrypt data

false = Do not encrypt data (Default)

Command

Length

Field Value

Get Version

1

The GET_VERSION command is used to retrieve information on the NTAG family, the product version, storage size and other product data required to identify the specific NTAG21x.

Byte 0 = 0x60

Command

Length

Field Value

Read

2

The READ command requires a start page address, and returns the 16 bytes of four NTAG21x pages. For example, if address is 03h then pages 03h, 04h, 05h, 06h are returned. Special conditions apply if the READ command address is near the end of the accessible memory area. The special conditions also apply if at least part of the addressed pages is within a password protected area.

Byte 0 = 0x30

Byte 1 = Start Page Address

Fast Read

3

The FAST_READ command requires a start page address and an end page address and returns the all n*4 bytes of the addressed pages. For example, if the start address is 03h and the end address is 07h then pages 03h, 04h, 05h, 06h and 07h are returned.

Byte 0 = 0x3A

Byte 2 = Start Page Address Byte 3 = End Page Address

Write

6

The WRITE command requires a block address, and writes 4 bytes of data into the addressed NTAG21x page.

Byte 0 = 0xA2

Byte 1 = Address to Write

Byte 2 to 5 = 4 Bytes of Data to Write

Compatibility Write

18

Command

Length

Field Value

READ_CNT

2

The READ_CNT command is used to read out the current value of the NFC one-way counter of the NTAG213, NTAG215 and NTAG216. The command has a single argument specifying the counter number and returns the 24-bit counter value of the corresponding counter. If the NFC_CNT_PWD_PROT bit is set to 1b the counter is password protected and can only be read with the READ_CNT command after a previous valid password authentication

Byte 0 = 0x39

Byte 1 = 0x02 (NFC Counter Address)

PWD_AUTH

5

A protected memory area can be accessed only after a successful password verification using the PWD_AUTH command. The AUTH0 configuration byte defines the protected area. It specifies the first page that the password mechanism protects. The level of protection can be configured using the PROT bit either for write protection or read/write protection. The PWD_AUTH command takes the password as parameter and, if successful, returns the password authentication acknowledge, PACK. By setting the AUTHLIM configuration bits to a value larger than 000b, the number of unsuccessful password verifications can be limited. Each unsuccessful authentication is then counted in a counter featuring anti-tearing support. After reaching the limit of unsuccessful attempts, the memory access specified in PROT, is no longer possible.

Byte 0 = 0x1B

Byte 1..4 = password (4 bytes)

READ_SIG

2

The READ_SIG command returns an IC specific, 32-byte ECC signature, to verify NXP Semiconductors as the silicon vendor. The signature is programmed at chip production and cannot be changed afterwards.

Byte 0 = 0x3C

Byte 1 = 0x00, RFU

Tag

Len

Value / Description

81

01

Tag Response Code 0x00 = Success 0x01 = Failed

82

var

Encryption Control Payload

If unencrypted:

Parameter

Description

data

Command to send to the NFC tag.

  • Get Version

  • Read

  • Fast Read

  • Write

  • Compatibility Write

  • Read_Cnt

  • PWD_Auth

  • Read_Sig

For details of the command see the NFC commands table below or D998200383 DynaFlex Family Programmer’s Manual (COMMANDS) section NFC/Mifare Pass Through Commands

lastCommand

Determines if this is the last NFC command to complete the operation.

true = This is the last command. Device will provide a single beep after receiving a successful response from the NFC tag. To send subsequent commands, the NFC tag must be activated by calling startTransaction() with NFC enabled.

false = Expect more commands (Default).

Either set to true or false, if the NFC tag command fails, device will provide a double beep.

encrypt

Determines if data returned is to be encrypted.

true = Encrypt data

false = Do not encrypt data (Default)

Parameter for data

Description

Byte 0

Status of User Selection:

0x00 = User Selection Request completed, see Selection Result 0x01 = User Selection Request aborted, cancelled by user 0x02 = User Selection Request aborted, timeout

Byte 1

The menu item selected by the user. This is a single byte zero based binary value.

Parameter

Description

transaction

An interface that contains the parameters for the transaction.

Parameter

Description

eventCallback

Name of a class or structure that implements the IEventSubscriber interface event.

Parameter

Description

eventCallback

Name of a class or structure that implements the IEventSubscriber Delegate interface event.

getDeviceControl

getDeviceInfo

Name

requestPAN

requestPIN

requestSignature

sendAuthorization

sendClassicNFCCommand

sendDESFireNFCCommand

sendNFCCommand

sendPlusNFCCommand

sendSelection

1.18 startTransaction

subscribeAll

unsubscribeAll

Maximum length of accepted PIN (=< 12).

Byte 0 – 0xB0 – Write the value from the Transfer Buffer into destination block number

Byte 1 – Destination Sector Number Byte 2 - Destination Block number Byte 3 – Key Type 0 = A, 1 = B Byte 4 to 9 = 6 Byte Key

var

var

The COMPATIBILITY_WRITE command is implemented to guarantee interoperability with the established MIFARE Classic PCD infrastructure, in case of coexistence of ticketing and NFC applications. Even though 16 bytes are transferred to NTAG21x, only the least significant 4 bytes (bytes 0 to 3) are written to the specified address. Set all the remaining bytes, 04h to 0Fh, to logic 00h.

Byte 0 = 0xA0

Byte 1 = Address to Write

Byte 2 to 17 = 16 Bytes of Data to Write (only least significant 4 bytes are written)

Note: This command is sent in 2 steps, which the Firmware will handle

(1) <CMD><Address to Write><CRCH><CRCL>

(2) <16 Bytes of Data to Write><CRCH><CRCL>

Tag

IDeviceControl IDevice.getDeviceControl();
DeviceInfo IDevice.getDeviceInfo();
string IDevice.Name();
bool IDevice.requestPAN(PANRequest panRequest, PINRequest pinRequest);
bool IDevice.requestPIN(PINRequest pinRequest); PINRequest:
bool IDevice.requestSignature(byte timeout);
bool IDevice.sendAuthorization(IData data);
bool IDevice.sendClassicNFCCommand(
81	0100 (Tag Respons Code)
82	82036D (Encryption Control)
        FC 820369 (NFC Data Container) 
                DF7A 820364 (NFC Data)
                        031391010F55047777772E6D616774656B2E636F6DFE00. . .
                                www.magtek.com
81	0100 (Tag Response code)
82	820389 (Encryption Control)
    DFDF59 820370 (Encrypted Data Primitive) 
            03679DC03B4CA607E3A7D2B52C8E9F1B5CD3D85E7368425. . .
    DFDF50 0A (Encrypted Data KSN) 
            FFFF9876543210200047
        DFDF51 01 (Encrypted Data Type) 
                80
bool IDevice.sendDESFireNFCCommand( 
    IData data,
    bool lastCommand, 
    bool encrypt);
81	0100 (Tag Respons Code)
82	82036D (Encryption Control)
    FC 820369 (NFC Data Container) 
    DF7A 820364 (NFC Data)
    031391010F55047777772E6D616774656B2E636F6DFE00. . .
    www.magtek.com
81	0100 (Tag Response code)
82	820389 (Encryption Control)
    DFDF59 820370 (Encrypted Data Primitive) 
            03679DC03B4CA607E3A7D2B52C8E9F1B5CD3D85E7368425. . .
    DFDF50 0A (Encrypted Data KSN) 
            FFFF9876543210200047
        DFDF51 01 (Encrypted Data Type) 
        80
bool IDevice.sendNFCCommand( 
        IData data,
        bool lastCommand, 
        bool encrypt);
bool IDevice.sendPlusNFCCommand( 
        IData data,
        bool lastCommand, 
        bool encrypt);
bool IDevice.sendSelection(IData data);
bool IDevice.startTransaction(
bool IDevice.subscribeAll(IEventSubscriber eventCallback);
bool IDevice.unsubscribeAll(IEventSubscriber eventCallback);