Create an instance of the IDevice from CoreAPI.getDeviceList() or from CoreAPI.createDevice(). Then use the functions described in this chapter.
This function cancels a transaction. A transaction can only be cancelled before a card is presented.
bool IDevice.cancelTransaction();Return Value:
Returns true if cancelled. Otherwise, returns false.
This function retrieves the capabilities of the device.
IDeviceCapabilities IDevice.getCapabilities();Return Value:
Returns IDeviceCapabilities
This function retrieves the connection information of the device.
ConnectionState IDevice.getConnectionState();Return Value:
Returns ConnectionInfo
This function retrieves the connection state of the device.
ConnectionState IDevice.getConnectionState();Return Value:
Returns ConnectionState
This function allows the host to get an IDeviceConfiguration to configure the device.
IDeviceConfiguration IDevice.getDeviceConfiguration();Return Value:
Returns IDeviceConfiguration.
This function retrieves the device control interface to the device.
Return Value:
Returns IDeviceControl
This function returns an information class of the device.
Return Value:
Returns DeviceInfo.
This function returns the name of the device assigned from createDevice().
Return Value:
Returns the name of the device.
This function prompts the user to present their card and enter a PIN. A card is presented so that the device can retrieve the PAN, which is used for Format blocks requiring a PAN. The encrypted PIN block (EPB) will be returned in the event OnEvent(). The data byte array may be passed to builder function PANDataBuilder.GetPANData();
For DynaFlex devices, this function starts a PIN session on the first call and shall be called again to send the PIN status to the device for completing the PIN session.
Return Value:
Returns true if successful. Otherwise, returns false.
This function prompts the user to enter a PIN. The host must supply the PAN if the Format block selected requires a PAN. The encrypted PIN block (EPB) will be returned in the event OnEvent(). The data byte array may be passed to builder function PINDataBuilder.GetPINData();
For DynaFlex devices, this function starts a PIN session on the first call and shall be called again to send the PIN status to the device for completing the PIN session.
Return Value: Returns true if successful. Otherwise, returns false.
This function prompts the user to enter a signature. The response data will be returned in the event OnEvent.
Return Value: Returns true of successful. Otherwise, returns false.
This function sends the Authorization Response Code (ARPC) blob to the device. The response data will be returned in the event OnEvent(). See 15.23C.4 Sample Code for how to process an EMV transaction.
Return Value: Returns true if successful. Otherwise, returns false.
This function sends a command to a NFC Mifare Classic Tag type 2. The NFC tag must first be activated by calling startTransaction() with NFC enabled.
Return Value: Returns true if successful. Otherwise, returns false.
If unencrypted:
If encrypted:
Example Unencrypted Payload
Example Encrypted Payload for Fast Read
This function sends a command to an NFC Mifare DESFire Light Tag Type 4. The NFC tag must first be activated by calling startTransaction() with NFC enabled.
Return Value: Returns true if successful. Otherwise, returns false.
This function sends a command to an NFC tag type 2. The NFC tag must first be activated by calling startTransaction() with NFC enabled.
Return Value:
Returns true if successful. Otherwise, returns false.
This function sends a command to a Mifare Plus NFC tag. The NFC tag must first be activated by calling startTransaction() with NFC enabled.
Return Value: Returns true if successful. Otherwise, returns false.
This function sends a user selection to the device. The response data will be returned in the event OnEvent.
Return Value: Returns true if successful. Otherwise, returns false.
This function starts a transaction. The transaction will be processed through multiple calls to the event OnEvent() or a completion handler.
Contains status and data of operations of return type IResult.
Contains status and data of operations of return type IResult.
Return Value:
None
This function allows the host to be notified of all events sent by the device.
Return Value:
Returns true if successful. Otherwise, returns false.
This function allows the host to no longer receive any events sent by the device.
Return Value:
Returns true if successful. Otherwise, returns false.
Tone
byte
Tone to play when prompting for the PIN. Usage:
0x00 = No sound
0x01 = One beep 0x02 = Two beeps
Format
byte
ISO format for the PIN block.
0x00 = ISO Format 0
0x01 = ISO Format 1
0x03 = ISO Format 3
0x04 = ISO Format 4
PAN
String
byte
Maximum length of accepted PIN (< 12).
Tone
byte
Tone to play when prompting for the PIN. Usage: 0x00 - No sound 0x01 - One beep 0x02 - Two beeps
Format
byte
ISO format for the PIN block.
PAN
String
First 12 digits of the Primary Account Number. Leave blank if not required by the ISO format for the PIN block.
14
Byte 0 – 0xC0 – Decrement Command Byte 1 – Source Sector Number Byte 2 – Source Block number Byte 3 – Key Type 0 = A, 1 = B Byte 4 to 9 = 6 Byte Key Byte 10 to 13 = 4 Byte Operand
Mifare Restore
10
Byte 0 – 0xC2 – Restore Command Byte 1 – Source Sector Number Byte 2 – Source Block number Byte 3 – Key Type 0 = A, 1 = B Byte 4 to 9 = 6 Byte Key
Mifare Transfer
10
Byte 0 – 0xB0 – Write the value from the Transfer Buffer into destination block number Byte 1 – Destination Sector Number Byte 2 – Destination Block number Byte 3 – Key Type 0 = A, 1 = B Byte 4 to 9 = 6 Byte Key
Compatibility Write
18
The COMPATIBILITY_WRITE command is implemented to guarantee interoperability with the established MIFARE Classic PCD infrastructure, in case of coexistence of ticketing and NFC applications. Even though 16 bytes are transferred to NTAG21x, only the least significant 4 bytes (bytes 0 to 3) are written to the specified address. Set all the remaining bytes, 04h to 0Fh, to logic 00h.
Byte 0 = 0xA0
Byte 1 = Address to Write
Byte 2 to 17 = 16 Bytes of Data to Write (only least significant 4 bytes are written)
Note: This command is sent in 2 steps, which the Firmware will handle
(1) <CMD><Address to Write><CRCH><CRCL>
(2) <16 Bytes of Data to Write><CRCH><CRCL>
READ_CNT
2
The READ_CNT command is used to read out the current value of the NFC one-way counter of the NTAG213, NTAG215 and NTAG216. The command has a single argument specifying the counter number and returns the 24-bit counter value of the corresponding counter. If the NFC_CNT_PWD_PROT bit is set to 1b the counter is password protected and can only be read with the READ_CNT command after a previous valid password authentication
Byte 0 = 0x39
Byte 1 = 0x02 (NFC Counter Address)
PWD_AUTH
5
A protected memory area can be accessed only after a successful password verification using the PWD_AUTH command. The AUTH0 configuration byte defines the protected area. It specifies the first page that the password mechanism protects. The level of protection can be configured using the PROT bit either for write protection or read/write protection. The PWD_AUTH command takes the password as parameter and, if successful, returns the password authentication acknowledge, PACK. By setting the AUTHLIM configuration bits to a value larger than 000b, the number of unsuccessful password verifications can be limited. Each unsuccessful authentication is then counted in a counter featuring anti-tearing support. After reaching the limit of unsuccessful attempts, the memory access specified in PROT, is no longer possible.
Byte 0 = 0x1B
Byte 1..4 = password (4 bytes)
READ_SIG
2
The READ_SIG command returns an IC specific, 32-byte ECC signature, to verify NXP Semiconductors as the silicon vendor. The signature is programmed at chip production and cannot be changed afterwards.
Byte 0 = 0x3C
Byte 1 = 0x00, RFU
Len |
Value / Description |
FC | var | NFC Data Container |
/DF7A | var | NFC Data |
If encrypted: |
Tag | Len | Value / Description |
/DFDF59 | var | Encrypted Data Primitive to be decrypted. |
/DFDF50 | var | Encrypted Data KSN |
/DFDF51 | 01 | Encrypted Data Encryption Type |
Parameter
Type
Description
Timeout
byte
Wait time in seconds.
PaymentMethods
List of PaymentMethod
List of the PaymentMethod enumeration.
MSR = For magnetic stripe cards.
Contact = For EMV chip cards.
Contactless = For NFC contactless cards. ManualEntry = Manually entry, no card. When set, other payment methods must not be included.
Barcode = For barcode.
BarcodeEncrypted = For barcode with encrypted response.
AppleVAS = For Apple VAS.
GoogleVAS = For Apple VAS.
NFC = For NFC tag.
Parameter
Type
Description
Timeout
byte
Wait time in seconds.
PINMode
byte
PIN mode.
0x00 = Enter PIN
0x01 = Enter PIN Amount 0x02 = Reenter PIN Amount 0x03 = Reenter PIN
0x04 = Verify PIN
For DynaFlex devices this is the User Interface Sequence:
0x01 = Present Card / Enter PIN (start session)
0x04 = Present Card / Enter PIN / Enter PIN Again (start session)
On the second call to requestPAN(), send the PIN status:
0xFD = Cancel PIN Session (end session) 0xFE = PIN Entry Failed (end session) 0xFF = PIN Entry Successful (end session)
MinLength
byte
Minimum length of accepted PIN (>= 4).
MaxLength
byte
Timeout
byte
Wait time in seconds.
PINMode
byte
PIN mode. Usage: 0x00 - Enter PIN 0x01 - Enter PIN Amount 0x02 - Reenter PIN Amount 0x03 - Reenter PIN 0x04 - Verify PIN For DynaFlex devices this is the User Interface Sequence: 0x00 - Enter PIN (start session) 0x02 - PIN Incorrect, Try Again (continue session) 0x03 - Enter PIN / Enter PIN Again (start session) 0x05 - Enter PIN Again (continue session) On the second call to requestPIN(), send the PIN status: 0xFD - Cancel PIN Session (end session) 0xFE - PIN Entry Failed (end session) 0xFF - PIN Entry Successful (end session)
MinLength
byte
Minimum length of accepted PIN (> 4).
data
Contains ARPC blob.
data
Command to send to the NFC tag. For details of the command see NFC Classic commands table below or D998200383 DynaFlex Family Programmer’s Manual (COMMANDS) section NFC/Mifare Pass Through Commands
lastCommand
Determines if this is the last NFC command to complete the operation. true = This is the last command. Device will provide a single beep after receiving a successful response from the NFC tag. To send subsequent commands, the NFC tag must be activated by calling startTransaction() with NFC enabled. false = Expect more commands (Default). Either set to true or false, if the NFC tag command fails, device will provide a double beep.
encrypt
Determines if data returned is to be encrypted. true = Encrypt data false = Do not encrypt data (Default)
Mifare Read
11
Byte 0 – 0x30 – Read Command Byte 1 – Sector Number to Read Byte 2 – Start Block Number Byte 3 – End Block Number Byte 4 – Key Type, 0 = A, 1 = B Byte 5 to 10 = 6 Byte Key
Mifare Write
var
Byte 0 – 0xA0 – Write Command Byte 1 – Sector Number to Write Byte 2 – Start Block Number Byte 3 – End Block Number Byte 4 – Key Type 0 = A, 1 = B Byte 5 to 10 = 6 Byte Key Byte 11 to x = Variable length Byte Data (16 bytes per block)
Mifare Increment
14
Byte 0 – 0xC1 – Increment Command Byte 1 – Source Sector Number Byte 2 – Source Block number Byte 3 – Key Type 0 = A, 1 = B Byte 4 to 9 = 6 Byte Key Byte 10 to 13 = 4 Byte Operand
81
var
Tag Response Code Byte 0 = 0x00 = Success Byte 0 = 0x01 = I/O Failed Byte 0 = 0x02 Authentication Failed Byte 1 = 0x01 = Block that Failed (optional)
82
var
Encryption Control Payload
FC
var
NFC Data Container
/DF7A
var
NFC Data
/DFDF59
var
Encrypted Data Primitive to be decrypted.
/DFDF50
var
Encrypted Data KSN
/DFDF51
01
Encrypted Data Encryption Type
data
Command to send to the NFC tag. See DESFire Data Sheet (MF2DLHX0). Should follow ISO 7816-4 APDU format.
For details of the command see
DynaFlex Family Programmer’s Manual section NFC/Mifare Pass Through Commands
lastCommand
Determines if this is the last NFC command to complete the operation.
true = This is the last command. Device will provide a single beep after receiving a successful response from the NFC tag. To send subsequent commands, the NFC tag must be activated by calling startTransaction() with NFC enabled.
false = Expect more commands (Default).
Either set to true or false, if the NFC tag command fails, device will provide a double beep.
encrypt
Determines if data returned is to be encrypted. true = Encrypt data false = Do not encrypt data (Default)
81
02
Tag Response (SW1 SW2). See DESFire Data Sheet (MF2DLHX0). Should follow ISO 7816-4 APDU format.
SW1 and SW2 of R-APDU
If card is not able to respond:
SW1 = 0x64, SW2 = 0x00
82
var
Encryption Control Payload tag data
· Data of R-APDU
FC
var
NFC Data Container
/DF7A
var
NFC Data
/DFDF59
var
Encrypted Data Primitive to be decrypted.
/DFDF50
var
Encrypted Data KSN
/DFDF51
01
Encrypted Data Encryption Type
Parameter
Description
data
Command to send to the NFC tag.
· Get Version
· Read
· Fast Read
· Write
· Compatibility Write
· Read_Cnt
· PWD_Auth
· Read_Sig
For details of the command see the NFC commands table below or DynaFlex Family Programmer’s Manual section NFC/Mifare Pass Through Commands
lastCommand
Determines if this is the last NFC command to complete the operation.
true = This is the last command. Device will provide a single beep after receiving a successful response from the NFC tag. To send subsequent commands, the NFC tag must be activated by calling startTransaction() with NFC enabled.
false = Expect more commands (Default).
Either set to true or false, if the NFC tag command fails, device will provide a double beep.
encrypt
Determines if data returned is to be encrypted.
true = Encrypt data
false = Do not encrypt data (Default)
Command
Length
Field Value
Get Version
1
The GET_VERSION command is used to retrieve information on the NTAG family, the product version, storage size and other product data required to identify the specific NTAG21x.
Byte 0 = 0x60
Read
2
The READ command requires a start page address, and returns the 16 bytes of four NTAG21x pages. For example, if address is 03h then pages 03h, 04h, 05h, 06h are returned. Special conditions apply if the READ command address is near the end of the accessible memory area. The special conditions also apply if at least part of the addressed pages is within a password protected area.
Byte 0 = 0x30
Byte 1 = Start Page Address
Fast Read
3
The FAST_READ command requires a start page address and an end page address and returns the all n*4 bytes of the addressed pages. For example, if the start address is 03h and the end address is 07h then pages 03h, 04h, 05h, 06h and 07h are returned.
Byte 0 = 0x3A
Byte 2 = Start Page Address Byte 3 = End Page Address
Write
6
Tag
Len
Value / Description
81
01
Tag Response Code 0x00 = Success 0x01 = Failed
82
var
Encryption Control Payload
If unencrypted:
Parameter
Description
data
Command to send to the NFC tag.
· Get Version
· Read
· Fast Read
· Write
· Compatibility Write
· Read_Cnt
· PWD_Auth
· Read_Sig
For details of the command see the NFC commands table below or DynaFlex Family Programmer’s Manual section NFC/Mifare Pass Through Commands
lastCommand
Determines if this is the last NFC command to complete the operation.
true = This is the last command. Device will provide a single beep after receiving a successful response from the NFC tag. To send subsequent commands, the NFC tag must be activated by calling startTransaction() with NFC enabled.
false = Expect more commands (Default).
Either set to true or false, if the NFC tag command fails, device will provide a double beep.
encrypt
Determines if data returned is to be encrypted.
true = Encrypt data
false = Do not encrypt data (Default)
Byte 0
Status of User Selection: 0x00 = User Selection Request completed, see Selection Result 0x01 = User Selection Request aborted, cancelled by user 0x02 = User Selection Request aborted, timeout
Byte 1
The menu item selected by the user. This is a single byte zero based binary value.
IData
Member
Type/ Format
Description
Status
StatusCode
Enumerated status code.
Data
IData*
IData
IData
Member
Type/ Format
Description
Status
StatusCode
Enumerated status code.
Data
IData*
IData
Parameter
Description
transaction
Instance of ITransaction.
handler
Completion handler.
Parameter
Description
delegate
Name of a class that implements the IEventSubscriber interface event.
Parameter
Description
delegate
Name of a class that implements the IEventSubscriber interface event.
Maximum length of accepted PIN (=< 12).
MaxLength
Mifare Decrement
The WRITE command requires a block address, and writes 4 bytes of data into the addressed NTAG21x page.
Byte 0 = 0xA2
Byte 1 = Address to Write
Byte 2 to 5 = 4 Bytes of Data to Write
Tag
IDeviceControl IDevice.getDeviceControl();DeviceInfo IDevice.getDeviceInfo();string IDevice.Name();bool IDevice.requestPAN(PANRequest panRequest, PINRequest pinRequest);bool IDevice.requestPIN(PINRequest pinRequest); bool IDevice.requestSignature(byte timeout);bool IDevice.sendAuthorization(IData data);bool IDevice.sendClassicNFCCommand(
IData data,
bool lastCommand,
bool encrypt);81 0100 (Tag Respons Code)
82 82036D (Encryption Control)
FC 820369 (NFC Data Container)
DF7A 820364 (NFC Data)
031391010F55047777772E6D616774656B2E636F6DFE00. . .
www.magtek.com81 0100 (Tag Response code)
82 820389 (Encryption Control)
DFDF59 820370 (Encrypted Data Primitive)
03679DC03B4CA607E3A7D2B52C8E9F1B5CD3D85E7368425. . .
DFDF50 0A (Encrypted Data KSN)
FFFF9876543210200047
DFDF51 01 (Encrypted Data Type)
80bool IDevice.sendDESFireNFCCommand(
IData data,
bool lastCommand,
bool encrypt);81 0100 (Tag Respons Code)
82 82036D (Encryption Control)
FC 820369 (NFC Data Container)
DF7A 820364 (NFC Data)
031391010F55047777772E6D616774656B2E636F6DFE00. . .
www.magtek.com81 0100 (Tag Response code)
82 820389 (Encryption Control)
DFDF59 820370 (Encrypted Data Primitive)
03679DC03B4CA607E3A7D2B52C8E9F1B5CD3D85E7368425. . .
DFDF50 0A (Encrypted Data KSN)
FFFF9876543210200047
DFDF51 01 (Encrypted Data Type)
8081 0100 (Tag Response code)
82 820389 (Encryption Control)
DFDF59 820370 (Encrypted Data Primitive)
03679DC03B4CA607E3A7D2B52C8E9F1B5CD3D85E7368425. . .
DFDF50 0A (Encrypted Data KSN)
FFFF9876543210200047
DFDF51 01 (Encrypted Data Type)
8081 0100 (Tag Respons Code)
82 82036D (Encryption Control)
FC 820369 (NFC Data Container)
DF7A 820364 (NFC Data)
031391010F55047777772E6D616774656B2E636F6DFE00. . .
www.magtek.com81 0100 (Tag Response code)
82 820389 (Encryption Control)
DFDF59 820370 (Encrypted Data Primitive)
03679DC03B4CA607E3A7D2B52C8E9F1B5CD3D85E7368425. . .
DFDF50 0A (Encrypted Data KSN)
FFFF9876543210200047
DFDF51 01 (Encrypted Data Type)
80bool IDevice.sendPlusNFCCommand(
IData data,
bool lastCommand,
bool encrypt);bool IDevice.sendSelection(IData data);(BOOL) startTransaction: (IResult@property (nonatomic) MTU_StatusCode status;
@property (nonatomic, strong) IData* data;
(IResult*) status:(MTU_StatusCode) Status data: (IData*) Data;ITransaction* transaction);
(void) startTransaction: (IResult@property (nonatomic) MTU_StatusCode status;
@property (nonatomic, strong) IData* data
(IResult*) status:(MTU_StatusCode) Status data: (IData*) Data;ITransaction* transaction)
completionHandler: (BooleanCallback) handler;(Boolean) subscribeAll: (id<IEventSubscriber>) delegate;(Boolean) unsubscribeAll: (id<IEventSubscriber>) delegate;