0x00 = NORMAL_BATTERY_CHARGING
0x01 = DYNAMIC_BATTERY_CHARGING
When the device is in NORMAL_BATTERY_CHARGING mode it charges continuously until full, if it is connected to a dedicated charger or a USB host device like a tablet.
When the device is VBUS_BATTERY_DYNAMIC_CHARGING mode the device will run off the battery only until it reaches the battery charge percentage defined in Property 1.2.2.2.1.4 Battery Charging Start Level, then it will charge until it reaches the battery charge percentage defined in Property 1.2.2.2.1.5 Battery Charging Stop Level. In this mode it will repeat this cycle repeatedly. However, if the device is connected to dedicated charger, it will charge until full and not run off the battery unless the charger is disconnected.
The Property 1.2.2.2.1.6 Battery Charging Schedule feature can optionally be enabled while in DYNAMIC_BATTERY_CHARGING mode. When ON-DUTY the charging behavior is as described above When OFF-DUTY it will charge until full and not run off the battery until ON-DUTY.