0x1807 - LED Control

The host uses this command to control the 4 LEDs of the device when the device is not in non-User Control LED states. If the host sets an LED timer, the device reports completion via Notification User Interface Operation Complete - 0x1805 after the LED operation finishes.

Non-User Control LED state is when the device is in tamper, or currently running transaction with these commands:

  • Start Transaction - Command 0x1001

  • Card Emulation - Command 0x1840

  • Request PIN with Host Supplied Account Data - Command 0x2001

  • Request PIN with Card Supplied Account Data - Command 0x2002

When the device is in non-User Control LED states, it will return error if the host sends this command.

When the device is in the User Control LED state, and if there is any transaction that uses LEDs for the transaction status, the device will stop the User Control LEDs for that transaction to take over, and resume to the current system’s LED status after finishing that transaction.

The host is responsible for stopping the User Control LEDs so the device can get back to the system’s LEDs status if the device is in the User Control LEDs.

1807 = LED Control - β€ŽCommand 0x1807 –

81 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb

02

Byte 1 - User Control LED

  • 0x00 – Stop User Control LED. This will stop User control LED and resume the current system’s LED status.

  • 0x01 – Start User Control LED.

Byte 2 – Duration in unit of second

B

R

82

02

Byte 1 - LED number

  • Bit 1 = LED 1

  • Bit 2 = LED 2

  • Bit 3 = LED 3

B

R

End of any wrappers, at minimum including Request Message

No parameters.

End of any wrappers, at minimum including Response Message

Tag

Len

Value / Description

Typ

Req

Default

Beginning of any wrappers, at minimum including Request Message

Tag

Len

Value / Description

Typ

Req

Default

Beginning of any wrappers, at minimum including Response Message

AA 00 81 04 82 8D 18 07 82 04 01 00 00 00
AA 00 81 04 82 8D 18 07 82 04 01 00 00 00

Note:

  • DynaFlex II PED and DynaFlexII LEDs color can be GREEN, RED, AMBER, or BLUE.

  • DynaProx, DynaFlex II GO LEDs color is GREEN only. Setting other colors is the same as GREEN.

LED Control - Request Data for Command 0x1807 –

LED Control - Response Data for Command 0x1807

Request Example

Response Example

0x00 – Continuous
  • 0x01 to 0xFF = 1 to 255 seconds

  • Bit 4 = LED 4

    Where the LEDs are numbered 1, 2, 3, 4 counting from the left.

    Example: 0x01 = LED 1, 0x03 = LED 1 and LED 2.

    Byte 2 - LED Status

    • 0x00 = OFF

    • 0x01 = GREEN ON

    • 0x02 = GREEN BLINK FAST (1/4 second on, 1/4 second off)

    • 0x03 = GREEN BLINK SLOW (1/2 second on, 1/2 second off)

    • 0x04 = GREEN FLASH (1/4 second on, 3/4 second off)

    • 0x05 = GREEN FLASH QUICK (1/8 second on, 7/8 second off)

    • 0x11 = RED ON

    • 0x12 = RED BLINK FAST (1/4 second on, 1/4 second off)

    • 0x13 = RED BLINK SLOW (1/2 second on, 1/2 second off)

    • 0x14 = RED FLASH (1/4 second on, 3/4 second off)

    • 0x15 = RED FLASH QUICK (1/8 second on, 7/8 second off)

    • 0x21 = AMBER ON

    • 0x22 = AMBER BLINK FAST (1/4 second on, 1/4 second off)

    • 0x23 = AMBER BLINK SLOW (1/2 second on, 1/4 second off)

    • 0x24 = AMBER FLASH (1/4 second on, 3/4 second off)

    • 0x25 = AMBER FLASH QUICK (1/8 second on, 7/8 second off)

    • 0x31 = BLUE ON

    • 0x32 = BLUE BLINK FAST (1/4 second on, 1/4 second off)

    • 0x33 = BLUE BLINK SLOW (1/2 second on, 1/4 second off)

    • 0x34 = BLUE FLASH (1/4 second on, 3/4 second off)