> For the complete documentation index, see [llms.txt](https://developer.magtek.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://developer.magtek.com/api-and-command-reference/dynafamily-programmers-manual/properties/1.2.nnnn-device-settings/1.2.8.1.2.n-keyboard-emulation-configuration-select-data-draft-11-6-2026.md).

# 1.2.8.1.2.n - Keyboard Emulation Configuration - Select Data (draft 11/6/2026)

Select Data OIDs control which producers may emit keyboard output. For example, this component defines OID: [**Property 1.2.8.1.2.1 KBEMU Enable Profile**](#property_1.2.8.1.2.1-_select_data_-_kbem), a producer enable bitmask. Additional Select Data OIDs may be added later under 1.2.8.1.2.x.

Select Data is separate from [**Configuration 1.2.8.1.1.n**](https://developer.magtek.com/api-and-command-reference/dynafamily-programmers-manual/properties/1.2.nnnn-device-settings/1.2.8.1.1.n-keyboard-emulation-configuration-draft-11-6-2026). Configuration still holds [**Property 1.2.8.1.1.1 Keyboard Emulation Enable**](https://developer.magtek.com/api-and-command-reference/dynafamily-programmers-manual/properties/1.2.nnnn-device-settings/1.2.8.1.1.n-keyboard-emulation-configuration-draft-11-6-2026#property_1.2.8.1.1.1-_keyboard_emulation) and [**Property 1.2.8.1.1.2 Keyboard Emulation Rate**](https://developer.magtek.com/api-and-command-reference/dynafamily-programmers-manual/properties/1.2.nnnn-device-settings/1.2.8.1.1.n-keyboard-emulation-configuration-draft-11-6-2026#property_1.2.8.1.1.2-_keyboard_emulation). Both Keyboard Emulation Enable and a matching KBEMU Enable Profile bit must be set for a producer to send keyboard output.

## Property 1.2.8.1.2.1 - Select Data – KBEMU Enable Profile <a href="#property_1.2.8.1.2.1-_select_data_-_kbem" id="property_1.2.8.1.2.1-_select_data_-_kbem"></a>

This property is a 2-byte producer enable bitmask. Each defined bit enables or disables one producer. Financial and non-financial producers share the same bitmask. Bit 0 is the least significant bit of the 16-bit value (mask 0x0001). Bits 8–15 are reserved and must be written as 0.

<table data-header-hidden data-search="false"><thead><tr><th width="196.3333740234375" valign="top"></th><th></th></tr></thead><tbody><tr><td colspan="2" valign="top"><strong>Property Description</strong></td></tr><tr><td valign="top">Property OID</td><td>1.2.8.1.2.1 / 0x010208010201</td></tr><tr><td valign="top">Name</td><td>Select Data: KBEMU Enable Profile</td></tr><tr><td valign="top"><p> </p><p> </p><p> </p><p> </p><p> </p><p> </p><p> </p><p> </p><p> </p><p>Description</p></td><td><p>The KBEMU Enable Profile property is a 2-byte producer enable bitmask. Each bit enables or disables one producer. The global property <a href="https://developer.magtek.com/api-and-command-reference/dynafamily-programmers-manual/properties/1.2.nnnn-device-settings/1.2.8.1.1.n-keyboard-emulation-configuration-draft-11-6-2026"><strong>Keyboard Emulation Enable (1.2.8.1.1.1)</strong></a> must also be enabled for any keyboard output. Bit 0 is the least significant bit of the 16-bit value (mask 0x0001). Reserved bits must be written as 0.</p><p></p><p><strong>Bit</strong>   <strong>Mask</strong>       <strong>Producer</strong><br>---    ------      -------------------<br>0       0x0001    EMV Contact<br>1        0x0002   EMV Contactless<br>2       0x0004   EMV MSR<br>3       0x0008   EMV Manual Entry<br>4       0x0010    MSR (Non-Financial)<br>5       0x0020   Barcode<br>6       0x0040   MIFARE<br>7       0x0080   Personal Info<br>8-15  0xFF00   Reserved</p><p><strong>Example</strong><br>0x00C6 enables EMV Contactless, EMV MSR, MIFARE, Personal Info</p></td></tr><tr><td valign="top">Securing Key</td><td>None</td></tr><tr><td valign="top">Min. Len (b)</td><td>2</td></tr><tr><td valign="top">Max. Len (b)</td><td>2</td></tr><tr><td valign="top">Data Type</td><td>Binary</td></tr><tr><td valign="top">Valid Values</td><td>0x0000 – 0x00FF</td></tr><tr><td valign="top">Default</td><td>0x00FF (all producers enabled)</td></tr></tbody></table>

**Get Request Example**

<table data-header-hidden><thead><tr><th valign="top"></th></tr></thead><tbody><tr><td valign="top">Example (Hex)</td></tr><tr><td valign="top">AA0081040155D101840FD1018501018704020801028902C100</td></tr></tbody></table>

**Get Response Example**

<table data-header-hidden><thead><tr><th valign="top"></th></tr></thead><tbody><tr><td valign="top">Example (Hex)</td></tr><tr><td valign="top">AA0081048255D10182040000000084820011D1018501018704020801028904C10200FF</td></tr></tbody></table>

**Set Request Example**

<table data-header-hidden><thead><tr><th valign="top"></th></tr></thead><tbody><tr><td valign="top">Example (Hex)</td></tr><tr><td valign="top">AA00 81040155 D111 8411 D111 850101 870402080102 8904 C10200FF</td></tr></tbody></table>

**Set Response Example**

<table data-header-hidden><thead><tr><th valign="top"></th></tr></thead><tbody><tr><td valign="top">Example (Hex)</td></tr><tr><td valign="top">AA0081048255D11182040000000084820011D1118501018704020801028904C10200FF</td></tr></tbody></table>

## Property 1.2.8.1.2.2 - Select Data – KBEMU EMV Subtype Enable <a href="#property_1.2.8.1.2.2-_select_data_-_kbem" id="property_1.2.8.1.2.2-_select_data_-_kbem"></a>

This property is a 1-byte bitmask that enables or disables EMV keyboard-output subtypes. Bit 0 enables ARQC. Bit 1 enables Batch. The same mask applies to EMV Contact, EMV Contactless, EMV MSR, and EMV Manual Entry. Non-financial producers (MSR Non-Financial, Barcode, MIFARE, and Personal Info) do not use this property. Bit 0 is the least significant bit (mask 0x01). Bits 2–7 are reserved and must be written as 0.

<table data-header-hidden data-search="false"><thead><tr><th width="195.66665649414062" valign="top"></th><th></th></tr></thead><tbody><tr><td colspan="2" valign="top"><strong>Property Description</strong></td></tr><tr><td valign="top">Property OID</td><td>1.2.8.1.2.2 / 0x010208010202</td></tr><tr><td valign="top">Name</td><td>Select Data: KBEMU EMV Subtype Enable</td></tr><tr><td valign="top"><p> </p><p> </p><p> </p><p> </p><p> </p><p> </p><p> </p><p>Description</p></td><td><p>The KBEMU EMV Subtype Enable property is a 1-byte bitmask. Each defined bit enables or disables one EMV keyboard-output subtype. <a href="https://developer.magtek.com/api-and-command-reference/dynafamily-programmers-manual/properties/1.2.nnnn-device-settings/1.2.8.1.1.n-keyboard-emulation-configuration-draft-11-6-2026"><strong>Keyboard Emulation Enable (1.2.8.1.1.1)</strong></a> and the matching producer bit in <a href="https://developer.magtek.com/api-and-command-reference/dynafamily-programmers-manual/properties/1.2.nnnn-device-settings/1.2.8.1.1.n-keyboard-emulation-configuration-draft-11-6-2026"><strong>KBEMU Enable Profile (1.2.8.1.2.1)</strong></a> must also be set. An EMV ARQC or Batch job is typed only when all three are enabled. Bit 0 is the least significant bit (mask 0x01). Reserved bits must be written as 0.</p><p></p><p><strong>Bit</strong>  <strong>Mask</strong>   <strong>EMV Subtype</strong><br>---   ------  -------------------<br>0      0x01    ARQC Enable<br>1      0x02    Batch Enable<br>2-7  0xFC   Reserved Example</p><p><br><strong>Example</strong><br>0x01 enables ARQC only</p><p></p><p><strong>NOTE</strong>: When both ARQC and Batch are enabled (0x03), the device outputs the ARQC record first, followed by the Batch record. A single space (0x20) is inserted between the two records, before the Batch prefix. No separator is added when only one subtype is enabled, or when the ARQC output was not sent.</p></td></tr><tr><td valign="top">Securing Key</td><td>None</td></tr><tr><td valign="top">Min. Len (b)</td><td>1</td></tr><tr><td valign="top">Max. Len (b)</td><td>1</td></tr><tr><td valign="top">Data Type</td><td>Binary</td></tr><tr><td valign="top">Valid Values</td><td>0x00 – 0x03 (reserved bits must be 0)</td></tr><tr><td valign="top">Default</td><td>0x01 (ARQC only)</td></tr></tbody></table>

**Get Request Example**

<table data-header-hidden><thead><tr><th valign="top"></th></tr></thead><tbody><tr><td valign="top">Example (Hex)</td></tr><tr><td valign="top">AA0081040155D101840FD1018501018704020801028902C200</td></tr></tbody></table>

**Get Response Example**

<table data-header-hidden><thead><tr><th valign="top"></th></tr></thead><tbody><tr><td valign="top">Example (Hex)</td></tr><tr><td valign="top">AA0081048255D10182040000000084820010D1018501018704020801028903C20101</td></tr></tbody></table>

**Set Request Example**

<table data-header-hidden><thead><tr><th valign="top"></th></tr></thead><tbody><tr><td valign="top">Example (Hex)</td></tr><tr><td valign="top">AA0081040155D1118410D1118501018704020801028903C20101</td></tr></tbody></table>

**Set Response Example**

<table data-header-hidden><thead><tr><th valign="top"></th></tr></thead><tbody><tr><td valign="top">Example (Hex)</td></tr><tr><td valign="top">AA0081048255D11182040000000084820010D1118501018704020801028903C20101</td></tr></tbody></table>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://developer.magtek.com/api-and-command-reference/dynafamily-programmers-manual/properties/1.2.nnnn-device-settings/1.2.8.1.2.n-keyboard-emulation-configuration-select-data-draft-11-6-2026.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
